➡️Product description
Features
- Durable IP66 Transmitter Housing: With multifunctional display and glass-protected keypad.
- Bidirectional Measurement: With collector functions and process input, output, and serial connection options, including Modbus RTU and HART*.
- Optional Temperature Compensation: PT100 sensors are available for temperature-compensated measurement.
- Optional Sound Speed Output Function: For recognizing non-contact products and interface scanning; optional internal data logger with a capacity of up to 100,000 measurements.
- Hazardous Area Compatibility: Transmitter and transducers are suitable for use in hazardous areas Zone 1 and 2.
- KATdata+ Software: For offline/online data transfer with serial connection interface options.
- Optional Stainless Steel Housing: For durability in harsh weather conditions and flow meters with 1 or 2 Measurement Channels: With graphical LCD display, internal data logger, and input/output options.
- Wide Range of Pipe Types and Diameters: From 10mm to over 3 meters.
- Easy Installation: With installation wizard and voice-guided sensor positioning assistant TM for simple and quick setup.
- Dual DSP Technology: For improved measurement accuracy using transit-time correlation measurement.
- Special Solution for Hazardous Areas: With a glass-protected keypad for Zone 1 and 2.
- Optional Stainless Steel Casing: For added protection.
Description:
KATflow clamp-on flow meters operate using the transit-time method. This method is based on the principle that sound waves move faster with the flow of the fluid than against it. The difference in transit time is directly proportional to the flow velocity of the fluid and, consequently, to the volumetric flow rate. The ultrasonic transducers (sensors) of the flow meter are mounted on the outside surface of the pipe and are used to generate and receive the pulses. The time differences created by the ultrasonic signals in the flowing fluid are evaluated by the flow meter to obtain an accurate flow measurement. The improved electronic circuits of the flow meter adapt to and compensate for changes in ambient temperature and flow profile, ensuring reliable measurements. The KATflow 170 is a fixed-type clamp-on ultrasonic flow meter designed for non-intrusive and non-invasive flow measurements of liquids and liquefied gases in fully filled pipes. It can be supplied with one or two measurement channels, allowing the flow meter to monitor up to two separate pipes simultaneously. Alternatively, a dual-channel configuration can be used for two-way sensor mounting on a single pipe. Additionally, the KATflow 170 offers optional features for process input, output, and serial connection, including concentration measurement and temperature-compensated flow measurement. These features are complemented by an optional internal data logger and software for recording and downloading measured values. The intuitive device menu allows for setup and accurate sensor mounting in minutes with the Installation Wizard and Voice Sensor Positioning Assistant TM. The flow meter is suitable for use in Zones 1 and 2, and is programmed with a magnetic pen for secure use in hazardous areas.
Contact
- Type: RS 485 (optional), Modbus RTU (optional)
- Data Transmission: Measured and integrated values, parameter settings and configuration, data input
- Internal Data Logging:
- Storage Capacity: Approximately 30,000 measurements (with selectable measurement units up to 10), 5 MB log size. Up to approximately 100,000 measurements (with selectable measurement units up to 10), 16 MB logger size.
- Recorded Data: All measured and integrated values, parameter settings.
- KATdata + Software:
- Functionality: Download values/parameter settings, graphical presentation, list format, third-party software export, online data transfer.
- Operating Systems: Windows 7, Vista, XP, NT, 2000; Linux; Mac (optional).
- .
Quantity and Measurement Units:
- Volumetric Flow: m³/h, m³/min, m³/s, l/h, l/min, l/s, USgal/h (US gallon per hour), USgal/min, USgal/s, bbl/day (barrel per day), bbl/s, bbl/min.
- Flow Velocity: m/s, ft/s, in/s.
- Mass Flow Rate: g/s, t/h, kg/h, kg/min.
- Volume: m³, l, gal (US gallon), barrel.
- Mass: g, kg, t.
- Temperature: °C (only with temperature compensation).
Değerlendirmeler